Buscar
Mostrando ítems 1-3 de 3
Dimensional characterization of large opaque samples and microdeformations by low coherence interferometry
(2020-01-25)
We report on the application of an interferometric system based on the low-coherence interferometry technique to the dimensional characterization of large opaque mechanical parts as well as microdeformations experienced ...
Interferometric system based on swept source-optical coherence tomography scheme applied to the measurement of distances of industrial interest
(2015-12-11)
We used an interferometric technique based on typical optical coherence tomography (OCT)
schemes for measuring distances of industrial interest. The system employed as a light source a tunable erbium-doped fiber laser of ...
Application of a long-rangesweptsource optical coherence tomography-based scheme for dimensional characterization of multilayer transparent objects
(2017-08-18)
This work presents the use of a recently develop edinter ferometric system based on the swept source optical coherence tomography (SS-OCT) technique, which allows the characterization of transparent and semitransparent ...