dc.description.abstractLos aceros inoxidables martensíticos como el AISI 420 tienen múltiples aplicaciones, entre ellas instrumentos quirúrgicos, donde se requiere buena resistencia al desgaste y a la corrosión. Los tratamientos de modificación superficial, como la nitruración iónica, permiten mejorar las propiedades mecánicas de estos aceros pero afectan su resistencia a la corrosión. Por esta razón, un tratamiento posterior de deposición de un recubrimiento tipo DLC (Diamond Like Carbon) puede ser conveniente. En este trabajo se estudió el comportamiento al desgaste y a la corrosión de muestras dúplex (nitruradas y recubiertas por PACVD) y se compararon con muestras nitruradas, sólo recubiertas, nitruradas y sin ningún tratamiento más que templado y revenido. Se analizaron los recubrimientos con espectroscopia Raman y EDS. Se realizaron ensayos de pin on disk y se evaluó la adhesión mediante ensayos de Scratch Test e indentación Rockwell C. Se midió nanodureza con indentador Berkovich. Se llevaron a cabo los ensayos propuestos para instrumentos quirúrgicos en la Norma F 1089-02 (prueba de agua hirviendo y de hisopado con sulfato de cobre) y ensayos de corrosión en niebla salina. Estos recubrimientos tienen bajo contenido de hidrógeno, aproximadamente un 20 %. El espesor de los recubrimientos fue de 2 μm y la dureza alcanzó 24 GPa. La capa nitrurada tuvo un espesor de 10 μm. Las muestras dúplex y recubiertas presentaron bajo coeficiente de fricción y el volumen desgastado fue indetectable. Además, tuvieron buen comportamiento a la corrosión en el ensayo de niebla salina y en los ensayos propuestos en la Norma F 1089-02. No obstante, la muestra sólo nitrurada presentó una región corroída en el ensayo de sulfato de cobre y en el de agua hirviendo. La muestra dúplex presentó mejor adhesión que la muestra sólo recubierta en los ensayos de Scratch Test y de indentación Rockwell C.es_ES
dc.description.abstractMartensitic stainless steels can be used in different applications such as surgical instruments where a good wear and corrosion resistance are required. The diffusion treatments such as nitriding improve the mechanical properties of these steels, however; they affect the corrosion resistance. For this reason, the DLC (Diamond Like Carbon) coatings deposition can be convenient. The wear and corrosion behaviour was studied in duplex samples (nitrided and PACVD coated) and they were compared with nitrided, only coated and samples with no treatment, but quench and tempering. The coatings were analyzed by Raman spectroscopy and EDS. Pin on disk tests were performed to determine wear resistance and the adhesion was evaluated using Scratch Test and Rockwell C Indentation. The nanohardness was measured with a Berkovich indenter. The corrosion tests for surgical instruments (according to the ASTM Standard F 1089 -02) and Spray Salt Fog corrosion tests were also carried out.The DLC coatings had about 20% hydrogen content and thickness was 2 μm, while the hardness reached 24 GPa. The nitrided layer thickness beneath was 10 μm. The duplex and coated samples presented low friction coefficient and the wear volume loss was undetectable. The coatings had good corrosion behaviour in the corrosion tests. Nevertheless, the nitrided samples did not pass the copper sulfate test and they showed corrosion signs in the boil tests. The duplex samples had better adhesion than the coated samples in scratch test and indentation Rockwell C.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.rights.uriAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.subjectAcero-instrumentos quirúrgicoses_ES
dc.titleProtección de acero para instrumentos quirúrgicos con recubrimientos duros en base carbono tipo DLCes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.rights.holderDalibón Bähler, Eugenia Laura ; Trava-Airoldi, Vladimir Jesús ; Brühl, Sonia Patricia ; Pecina, Jorge Nahuel ; Cabo, Amado.es_ES
dc.description.affiliationFil: Dalibón Bähler, Eugenia Laura. Universidad Tecnológica Nacional. Facultad Regional Concepción del Uruguay. Departamento Ingeniería Electromecánica. Grupo de Ingeniería de Superficies; Argentina.es_ES
dc.description.affiliationFil: Pecina, Jorge Nahuel. Universidad Tecnológica Nacional. Facultad Regional Concepción del Uruguay. Departamento Ingeniería Electromecánica. Grupo de Ingeniería de Superficies; Argentina.es_ES
dc.description.affiliationFil: Brühl, Sonia Patricia. Universidad Tecnológica Nacional. Facultad Regional Concepción del Uruguay. Departamento Ingeniería Electromecánica. Grupo de Ingeniería de Superficies; Argentina.es_ES
dc.description.affiliationFil: Cabo, Amado. IONAR SA; Argentina.es_ES
dc.description.affiliationFil: Trava-Airoldi, Vladimir Jesús. Ministério da Ciencia, Tecnologia e Innovacao. Instituto Nacional de Pesquisas Espaciais; Brasil.es_ES
dc.type.versionacceptedVersiones_ES
dc.rights.useNo comercial con fines académicos.es_ES


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess