2024-06-122024-06-122015http://hdl.handle.net/20.500.12272/10953Anode-cathode and nozzle-cathode voltages, plenum pressure and gas mass flow measurements in a low current (30 A) cutting torch, operated with oxygen gas, are used as inputs for an electrical model coupled to a simplified fluid model, in order to infer some properties of the plasma-gas structure that are difficult to measure.pdfengopenAccesshttp://creativecommons.org/licenses/by-nc-nd/4.0/Attribution-NonCommercial-NoDerivatives 4.0 Internacionalcutting torcharc voltagesnozzle modelInterpretation of Voltage Measurements in Cutting Torches.info:eu-repo/semantics/articlePrevosto, LeandroCreative Commons http://creativecommons.org/licenses/by-nc-nd/4.0/ Attribution-NonCommercial-NoDerivatives 4.0 Internacional Este trabajo puede ser utilizado con fines académicos y de estudio.10.1063/1.2405932