Mostrar el registro sencillo del ítem

dc.creatorVega, Jorge Rubén
dc.creatorClementi, Luis Alberto
dc.creatorArretxe, Zohartze
dc.creatorAguirreurreta, Ziortza
dc.creatorAgirre, Amaia
dc.creatorLeiza, José R.
dc.creatorGugliotta, Luis M.
dc.date.accessioned2018-09-14T22:27:15Z
dc.date.available2018-09-14T22:27:15Z
dc.date.issued2013
dc.identifier.urihttp://hdl.handle.net/20.500.12272/3122
dc.description.abstractCapillary hydrodynamic fractionation (CHDF) with turbidity detection at a single wavelength is an analytical technique that is often used for sizing the submicrometric particles of hydrophobic colloids. This article investigates three sources of errors that affect the particle size distribution (PSD) estimated by CHDF: diameter calibration errors, uncertainties in the particle refractive index (PRI), and instrumental broadening (IB). The study is based on simulated and experimental examples that involve unimodal and bimodal PSDs. Small errors in the diameter calibration curve can produce important deviations in the number average diameter due to systematic shifts suffered by the PSD modes. Moderate uncertainties in the PRI are unimportant in the analysis of unimodal PSDs, but in the specific case of bimodal PSDs, errors in the PRI can strongly affect the estimated number concentration of each mode. The typical IB correction (based on the IB function estimated from narrow standards) produces slightly erroneous average diameters but can lead to PSDs with underestimated widths and distorted shapes. In practice, the three investigated sources of errors can be present simultaneously, and uncertainties in the average diameters, the shape and width of the PSD, and the number concentration of the PSD modes are unavoidable.es_ES
dc.formatapplication/pdf
dc.language.isoenges_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectCapillaryes_ES
dc.subjectHydrophobic colloidses_ES
dc.titleCapillary hydrodynamic fractionation of hydrophobic colloids: errors in the estimated particle size distributiones_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.affiliationFil: Vega, Jorge Rubén. CONICET-Universidad Nacional del Litoral. INTEC; Argentina.es_ES
dc.description.affiliationFil: Vega, Jorge Rubén. Universidad Tecnológica Nacional. Facultad Regional Santa Fe; Argentina.es_ES
dc.description.affiliationFil: Clementi, Luis Alberto. CONICET-Universidad Nacional del Litoral. INTEC; Argentina.es_ES
dc.description.affiliationFil: Clementi, Luis Alberto. Universidad Tecnológica Nacional. Facultad Regional Santa Fe; Argentina.es_ES
dc.description.affiliationFil: Gugliotta, Luis M. CONICET-Universidad Nacional del Litoral. INTEC; Argentina.es_ES
dc.description.affiliationFil: Arretxe, Zohartze. Universidad del País Vasco. Facultad de Química. Departamento de Química Aplicada. POLYMAT; España.es_ES
dc.description.affiliationFil: Aguirreurreta, Ziortza. Universidad del País Vasco. Facultad de Química. Departamento de Química Aplicada. POLYMAT; España.es_ES
dc.description.affiliationFil: Agirre, Amaia. Universidad del País Vasco. Facultad de Química. Departamento de Química Aplicada. POLYMAT; España.es_ES
dc.description.affiliationFil: Leiza, José R.. Universidad del País Vasco. Facultad de Química. Departamento de Química Aplicada. POLYMAT; España.es_ES
dc.description.peerreviewedPeer Reviewedes_ES
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones_ES
dc.type.snrdinfo:ar-repo/semantics/artículoes_ES
dc.rights.useCondiciones de Uso libre desde su aprobaciónes_ES
dc.rights.useAtribución-NoComercial-CompartirIgual 4.0 Internacional*


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess