Mostrar el registro sencillo del ítem

dc.creatorCerrotta, Santiago
dc.creatorMorel, Eneas Nicolás
dc.creatorTorga, Jorge Román
dc.date.accessioned2020-08-31T23:26:00Z
dc.date.available2020-08-31T23:26:00Z
dc.date.issued2014
dc.identifier.citationSantiago Cerrotta - Morel, Eneas - Torga, Jorge-Scanning Optical Coherence Tomography Applied to the Characterization of Surfaces and Coatings - Procedia Materials Science Volume 9, 2015, Pages 142-149es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12272/4517
dc.description.abstractThis paper shows the technique of optical coherence tomography in the frequency domain (OCT-FD) to obtain surface topography and tomography of surface coatings. The setup is based on a superluminescent diode centered on 849 nm with an spectral wide of 50 nm as the light source, a single-mode fibre Michelson interferometer and a spectrometer as the detector system. This scheme allows having compact and robust equipments that was designed to be used in an industrial environment. With this system it can be obtain a tridimensional image acquired point by point with a maximum range of 20 mm width and length and 2 mm depth. Images obtained from the topography of metal samples and tomography of polymer based coatings is presented. Also it is shown that is possible to obtain, from these images, parameters of interest of the sample, such as roughness, flatness and characteristic distances. As an example to show the potential of the method the dimensions of a metal surface modified after laser ablation were measured from a topography image obtained with this technique. A second example presented was the image obtained of a roughness pattern made on a metal surface. Finally it was presented a tomography image of a modified polyurethane coating deposited on a metal surface. Thickness and refractive index of the coating were obtained after the image analysis.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherEl Sevieres_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.rights.uriAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.sourceProcedia Materials Science Volume 9, Pages 142-149 (2015)es_ES
dc.subjectUTNes_ES
dc.subjectFacultad Regional Deltaes_ES
dc.subjectOCTes_ES
dc.subjectLow Coherencees_ES
dc.subjectSurfaces Characterizationes_ES
dc.subjectOCTes_ES
dc.subjectProfilometryes_ES
dc.titleScanning optical coherence tomography applied to the characterization of surfaces and coatingses_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.rights.holderCerrotta, Santiagoes_ES
dc.description.affiliationFil: Cerrota, Santiago. Universidad Tecnológica Nacional. Facultad Regional Delta. Grupo Nanofotonica; Argentina.es_ES
dc.description.affiliationFil: Morel, Eneas Nicolás. Universidad Tecnológica Nacional. Facultad Regional Delta. Grupo Nanofotonica; Argentina.es_ES
dc.description.affiliationFil: Torga, Jorge Román. Universidad Tecnológica Nacional. Facultad Regional Delta. Grupo Nanofotonica; Argentina.es_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.relation.referenceshttps://www.sciencedirect.com/science/article/pii/S221181281500019Xes_ES
dc.rights.useAtribución – No Comercial – Compartir Igual (by-nc-sa)es_ES
dc.identifier.doi10.1016/j.mspro.2015.04.018