Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Gómez, Gonzalo"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • Thumbnail Image
    Item
    Ensayo de impulso en motores trifásicos de baja tensión y bobinado aleatorio: un caso de estudio que demuestra su efectividad.
    (IEEE, 2024) Gómez, Gonzalo
    Existe mucha experiencia y normativa vinculada a ensayos dieléctricos de motores eléctricos de 2,3kV o superiores para mantenimiento en campo, dejando a los motores de baja tensión limitados a mediciones de resistencia de aislamiento y resistencia de devanados. Sin embargo, ensayos como el surge test o de sobretensión continua son herramientas potentes para el diagnóstico en campo de motores eléctricos de baja tensión, que a pesar de ser económicos representan en muchos casos dificultades logísticas para su reemplazo y grandes pérdidas económicas por lucro cesante. En este artículo se expone un caso de estudio que manifiesta la utilidad de realizar ensayos de impulso en motores de baja tensión, aplicando los criterios que la normativa recomienda para motores de 2,3kV o superiores.
  • Thumbnail Image
    Item
    Surge testing in low-voltage three-phase motors with random winding: a case study demonstrating its effectiveness.
    (IEEE, 2024) Gómez, Gonzalo
    There is a lot of experience and regulations linked to dielectric testing of electric motors of 2.3kV or higher for field maintenance, leaving low voltage motors limited to measurements of insulation resistance and winding resistance. However, tests such as the surge test or continuous overvoltage test are powerful tools for field diagnosis of low voltage electric motors, which despite being economical, in many cases represent logistical difficulties for their replacement and large economic losses due to loss of profits. This article presents a case study that shows the usefulness of carrying out impulse tests on low voltage motors, applying the criteria that the regulations recommend for motors of 2.3kV or higher.

 

UTN | Rectorado

Sarmiento 440

(C1041AAJ)

Buenos Aires, Argentina

+54 11 5371 5600

SECRETARÍAS
  • Académica
  • Administrativa
  • Asuntos Estudiantiles
  • Ciencia y Tecnología
  • Consejo Superior
  • Coordinación Universitaria
  • Cultura y Extensión Universitaria
  • Igualdad de género y Diversidad
  • Planeamiento Académico y Posgrado
  • Políticas Institucionales
  • Relaciones Internacionales
  • TIC
  • Vinculación Tecnológica
  • Comité de Seguridad de la Información
ENLACES UTN
  • DASUTeN
  • eDUTecNe
  • APUTN
  • ADUT
  • FAGDUT
  • FUT
  • SIDUT
ENLACES EXTERNOS
  • Secretaría de Educación
  • CIN
  • CONFEDI
  • CONEAU
  • Universidades