Cost-based comparison between membrane systems and chemical absorption processes for CO2 capture from flue gas.
Fecha
2019-05-09Autor
Arias, Ana Marisa
Mores, Patricia Liliana
Scenna, Nicolás José
Caballero, José Antonio
Mussati, Miguel Ceferino
Mussati, Sergio Fabián
0000-0002-6716-6633
0000-0001-6026-142X
0000-0002-1129-8725
0000-0002-6104-5179
0000-0002-4132-0292
Metadatos
Mostrar el registro completo del ítemResumen
An optimization study of membrane-based separation systems for carbon dioxide capture from flue gas
of power plants is conducted, considering the possibility of employing up to four stages and using diverse
options to create the required driving force. By proposing a superstructure-based model, the number of
stages, recycle options, use of feed compression and/or permeate vacuum, driving force distribution
along each membrane stage, operating conditions and equipment sizes are simultaneously optimized in
order to minimize the total annual cost at high capture ratios and purity targets. Thus, different optimal
arrangements are obtained and the total cost is reduced in about 20% compared without employing vacuum. Besides the optimal number of stages diminishes with decreasing purity, but it is independent
of the capture ratio. Also, the total cost decreases with the increase of the membrane permeance
requiring lower values of operating pressure and membrane areas. Permeance values higher than 2400
GPU lead to lower number of stages and recycles for the same separation target. By contrast, a
sensitivity analysis shows that the total cost increases with the increase of the electricity price, capacity
factor, and capital recovery factor, which are the more influential parameters in the objective function.
Despite new optimal operating and design conditions are obtained when these parameters vary, no
modifications in the optimal arrangement are observed.