Buscar
Mostrando ítems 21-30 de 38
Reduction of measurement errors in OCT scanning
(Spie Digital Library, 2018-03-05)
Optical coherence tomography (OCT) is a non-destructive optical technique, which uses a light source with a wide band width that focuses on a point in the sample to determine the distance (strictly, the optical path ...
Low-coherence interferometry measurement of filling in porous silicon
(2018)
The determination of capillary filling dynamics in nanoporous structures and, in particular, the analysis of the filling fraction profile in the advancing wet front have been proposed as possible methods for characterizing ...
Preliminary study of a heterodyne detection system for optical coherence tomography signals
(2019-10-24)
A heterodyne detection system for optical coherence tomography signalsis presented and characterized. The system allows to expand the range of measurement and overcome the limitations of conventional systems which typically ...
Determinación del llenado capilar en silicio poroso mediante interferometría de baja coherencia
(2017)
La determinación de la dinámica de llenado capilar en estructuras nanoporosas y, en particular,
del perfil de la fracción de llenado en el frente de mojado se ha propuesto como un posible método de caracterización de la ...
Desarrollo de un equipo basado en un interferómetro de baja coherencia para medición de topografía y tomografía de materiales
(2017)
Este trabajo presenta los resultados de un proyecto del desarrollo de un equipo para realizar topografías y tomografías de materiales basado en una técnica óptica aplicado como ensayo no destructivo para la caracterización ...
Dimensional characterization of large opaque samples and microdeformations by low coherence interferometry
(2020-01-25)
We report on the application of an interferometric system based on the low-coherence interferometry technique to the dimensional characterization of large opaque mechanical parts as well as microdeformations experienced ...
Diseño y construcción de un módulo de microscopía de barrido por sondeo local y de un sistema de nanoposicionamiento de alta precisión para un microscopio multianálisis
(2014)
Este trabajo presenta la técncia de interferometrá de baja coherencia orientada a la obtención de topografiá de superficies y tomografía de materiales. Se decribe la idea general, se presentan distintos esquemas experimentales ...
Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus
(2015-10-29)
La interferometría de baja coherencia en el espacio de Fourier (OCT-FD) es una técnica que permite medir distancia con valores típicos de rango dinámico en el orden de 3 mm y resolución por debajo de los 10 µm. En este ...
Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus
(2015-10-29)
The low coherence interferometry in Fourier space (FD-OCT) is a technique to measure distance with
typical values of dynamic range in the order of 3 mm and resolution below 10 microns. In this paper
we propose to combine ...
Dynamic Detection of Thicknesses in Polymer Deformation Based on the Optical Coherence Interferometry Technique
(2015-07-31)
We describe the implementation of the optical coherence interferometry (OCT) technique in the dynamic
measurement of the deformation of polymers. The experimental set-up of the interferometer system and the signal processing ...