Mostrar el registro sencillo del ítem

dc.creatorPrevosto, Leandro
dc.creatorKelly, Héctor
dc.creatorMancinelli, Beatriz
dc.date.accessioned2024-03-08T20:04:28Z
dc.date.available2024-03-08T20:04:28Z
dc.date.issued2013
dc.identifier.citationReview of Scientific Instruments.es_ES
dc.identifier.urihttp://hdl.handle.net/20.500.12272/9676
dc.description.abstractThis work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plas mas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current re gion the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core.es_ES
dc.formatpdfes_ES
dc.language.isoenges_ES
dc.rightsopenAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.rights.uriAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.sourceReview of Scientific Instruments 84, 123506 (2013).es_ES
dc.subjectLangmuir probe.es_ES
dc.subjectCurrent-voltage.es_ES
dc.titleLangmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe.es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.holderPrevosto, Leandro.es_ES
dc.description.affiliationFil: Prevosto, Leandro. Universidad Tecnológica Nacional. Facultad Regional Venado Tuerto. Grupo de Descargas Eléctricas. Departamento Ingeniería Electromecánica. Santa Fe; Argentina.es_ES
dc.description.affiliationFil: Mancinelli, Beatriz. Universidad Tecnológica Nacional. Facultad Regional Venado Tuerto. Grupo de Descargas Eléctricas. Departamento Ingeniería Electromecánica. Santa Fe, Argentina.es_ES
dc.description.affiliationFil: Kelly, Héctor. Universidad Tecnológica Nacional. Facultad Regional Venado Tuerto. Grupo de Descargas Eléctricas. Departamento Ingeniería Electromecánica. CONICET. Santa Fe; Argentina.es_ES
dc.description.peerreviewedPeer Reviewedes_ES
dc.type.versionacceptedVersiones_ES
dc.rights.useCreative Commons http://creativecommons.org/licenses/by-nc-nd/4.0/ Attribution-NonCommercial-NoDerivatives 4.0 Internacional Este trabajo puede ser utilizado con fines académicos y de estudio.es_ES
dc.identifier.doi10.1063/1.4848916


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como openAccess