FRD - Investigación - Ciencia y Tecnología
Permanent URI for this communityhttp://48.217.138.120/handle/20.500.12272/1225
Browse
3 results
Search Results
Item Fabry Perot detector for low coherence interferometry(2023-06) Cerrotta, Santiago; Torga, Jorge Román; Morel, Eneas NicolásSe proponen dos diseños teóricos de detectores de intensidad para distintas longitudes de onda basados en cavidades Fabry Perot para ser aplicados en la técnica de interferometría de baja coherencia en el dominio de las frecuencias (FD-LCI). Un detector axial unidimensional que consta de una cavidad variable con un fotodiodo y otro detector radial con cavidad fija y con un array lineal o cámara. Se demostró su factibilidad teórica realizando simulaciones de haces gaussianos propagándose a través de cavidades con diferentes características. Se optimizaron los parámetros para que los detectores estén centrados en 850 nm, con rangos de 60 nm y resolución por debajo del nanómetro para haces de 500 µm de cintura, condiciones típicas de las fuentes y detectores usadas en FD-LCI. Además, el diseño contempla la posibilidad de usarlos simultáneamente.Item Long-range frequency domain low-coherence interferometry detector for industrial applications(2023-01) Cerrotta, Santiago; Torga, Jorge Román; Morel, Eneas NicolásA low-cost long-range frequency domain low-coherence interferometry (LCI) detector is presented: time Fourier domain LCI (TFD-LCI). Combining ideas of time domain and frequency domain techniques, the TFD-LCI detects the analog Fourier transform of the optical interference signal with no limitation for the maximum optical path, measuring the thickness of several centimeters with micrometer resolution. A complete characterization of the technique is presented with a mathematical demonstration, simulations, and experimental results. An evaluation of repeatability and accuracy is also included. Measurements of small and large monolayer and multilayer thicknesses were done. Characterization of the internal and external thicknesses of industrial products such as transparent packages and glass windshield is presented, showing the potentiality of TFD-LCI for industrial applications.Item Dual system increases the resolution of a low coherence interferometer system through a signal detector astigmatic focus(2015-10-29) Morel, Eneas Nicolás; Aguilar, Andres; Torga, Jorge RománThe low coherence interferometry in Fourier space (FD-OCT) is a technique to measure distance with typical values of dynamic range in the order of 3 mm and resolution below 10 microns. In this paper we propose to combine the interferometric technique with a technique that measures distances using astigmatic focus signal, allowing lead the resolution limit of less than 10 nm. The experimental scheme shown armed with both techniques and experimental results in displacement of a sample surface, controlled feedback system with a piezoelectric strain gauge which we have used as a reference system..