High efficiency and simple technique for controlling mechanisms by EMG signals.

dc.creatorDugarte, Nelson
dc.creatorAlvarez, Antonio
dc.creatorMercado, Gustavo
dc.creatorGonzález, Adolfo
dc.creatorDugarte, Edinson
dc.date.accessioned2024-09-30T12:53:57Z
dc.date.available2024-09-30T12:53:57Z
dc.date.issued2015-01-01
dc.description.abstractThis article reports the development of a simple and efficient system that allows control of mechanisms through electromyography (EMG) signals. The novelty about this instrument is focused on individual control of each motion vector mechanism through independent electronic circuits. Each of electronic circuit does positions a motor according to intensity of EMG signal captured. This action defines movement in one mechanical axis considered from an initial point, based on increased muscle tension. The final displacement of mechanism depends on individual's ability to handle the levels of muscle tension at different body parts. This is the design of a robotic arm where each degree of freedom is handled with a specific microcontroller that responds to signals taken from a defined muscle. The biophysical interaction between the person and the final positioning of the robotic arm is used as feedback. Preliminary tests showed that the control operates with minimal positioning error margins. The constant use of system with the same operator showed that the person adapts and progressively improves at control technique.es_ES
dc.description.affiliationUniversidad Tecnológica Nacional. Facultad Regional Mendoza, Argentinaes_ES
dc.description.peerreviewedPeer Reviewedes_ES
dc.formatpdfes_ES
dc.identifier.citationSABI 2015es_ES
dc.identifier.doi10.1088/1742-6596/705/1/012065
dc.identifier.urihttp://hdl.handle.net/20.500.12272/11539
dc.language.isoenges_ES
dc.rightsopenAccesses_ES
dc.rights.holderUniversidad Tecnológica Nacional. Facultad Regional Mendozaes_ES
dc.rights.urihttp://creativecommons.org/publicdomain/zero/1.0/*
dc.rights.uriCC0 1.0 Universal*
dc.rights.useCC BY (Autoría) CC BY-NC (Autoría – No Comercial)es_ES
dc.subjectEMG signals, Controlling mechanismses_ES
dc.titleHigh efficiency and simple technique for controlling mechanisms by EMG signals.es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.type.versionacceptedVersiones_ES

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Artículo12 - Brazo Biorobótico.pdf
Size:
849.42 KB
Format:
Adobe Portable Document Format
Description:
High efficiency and simple technique...