Revisiting no-load parameters in steady-state equivalent circuits for distribution transformers

dc.coverage.spatialInternacionales_ES
dc.creatorFerreyra, Diego M.
dc.date.accessioned2024-03-14T00:29:05Z
dc.date.available2024-03-14T00:29:05Z
dc.date.issued2021-12-27
dc.description.abstractIn typical single-phase steady-state equivalent circuits for distribution transformers, a parallel circuit branch is used to represent no-load conditions. Currently, in usual engineering practice and teaching, this branch is composed of a resistance and a reactance connected in a parallel arrangement. However, a series arrangement was once used by some authors for the same branch, naturally using different resistance and reactance values. Besides, a fairly recent teaching reference has been found to refer indirectly to such series arrangement, and it has also been frequently noted that several Electric Machinery students tend to erroneously adopt a series arrangement view for this branch. Although the parallel arrangement is far more common in the literature, it seems that its practical advantages should be more explicitly detailed. This work aims at providing practical justifications for such parallel arrangement to represent this branch, as opposed to a series arrangement.es_ES
dc.description.affiliationFil: Ferreyra, Diego M. Universidad Tecnológica Nacional. Facultad Regional San Francisco; Argentinaes_ES
dc.description.sponsorshipUniversidad Tecnológica Nacional: PID ENECBSF0008115es_ES
dc.formatpdfes_ES
dc.identifier.citationD. M. Ferreyra, "Revisiting no-load parameters in steady-state equivalent circuits for distribution transformers," 2021 IEEE URUCON, Montevideo, Uruguay, 2021, pp. 481-485, doi: 10.1109/URUCON53396.2021.9647323es_ES
dc.identifier.doi10.1109/URUCON53396.2021.9647323
dc.identifier.isbn'978-1-6654-2443-1
dc.identifier.urihttp://hdl.handle.net/20.500.12272/9743
dc.language.isoenges_ES
dc.language.isoenges_ES
dc.publisherIEEE, Institute of Electrical and Electronics Engineerses_ES
dc.rightsembargoedAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.rights.uriAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.use.es_ES
dc.subjectDistribution transformerses_ES
dc.subjectTransformer coreses_ES
dc.subjectSteady statees_ES
dc.subjectEquivalent circuitses_ES
dc.subjectNo-load parameterses_ES
dc.titleRevisiting no-load parameters in steady-state equivalent circuits for distribution transformerses_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.type.versionpublisherVersiones_ES

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Carátula - Revisiting no-load parameters in steady-state equivalent circuits for distribution transformers.pdf
Size:
129.94 KB
Format:
Adobe Portable Document Format
Description:
Artículo principal y único

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: