Erroneous data detection in the harmonic state estimation of a radial distribution system with distributed generation

dc.coverage.spatialInternacionales_ES
dc.creatorFerreyra, Diego M.
dc.creatorSarmiento, Ana C.
dc.creatorReineri, Claudio A.
dc.date.accessioned2024-03-26T00:42:00Z
dc.date.available2024-03-26T00:42:00Z
dc.date.issued2012-09-03
dc.description.abstractThe present article extends a previous work where a state estimation technique was applied to a power distribution system to determine the amplitudes and phase angles of the harmonic currents injected at its buses. The nodal harmonic voltage amplitudes and phase angles were presented as the state variables and the corresponding current parameters were then obtained indirectly through calculation from the resulting estimates. The model of a 50-Hz 13.2-kV 4-bus radial system was used, where the grid and a generator were connected at opposite ends of the system in a typical distributed generation configuration. In this article, said implementation is expanded with algorithms for the detection and identification of erroneous data (bad data) such as those which might be obtained from faulty or disconnected measuring instruments. Although traditional algorithms are implemented, this work is a contribution toward the validation of harmonic state estimation techniques applied to electric distribution systems.es_ES
dc.description.affiliationFil: Ferreyra, Diego M. Universidad Tecnológica Nacional. Facultad Regional San Francisco; Argentina.es_ES
dc.description.affiliationFil: Sarmiento, Ana C. Universidad Tecnológica Nacional. Facultad Regional San Francisco; Argentina.es_ES
dc.description.affiliationFil: Reineri, Claudio A. Universidad Nacional de Río Cuarto. Facultad de Ingeniería; Argentina.es_ES
dc.description.sponsorshipUniversidad Tecnológica Nacional: PID ENUTNSF0004472es_ES
dc.formatpdfes_ES
dc.identifier.citationD. M. Ferreyra, A. C. Sarmiento and C. A. Reineri, "Erroneous data detection in the harmonic state estimation of a radial distribution system with distributed generation," 2012 Sixth IEEE/PES Transmission and Distribution: Latin America Conference and Exposition (T&D-LA), Montevideo, Uruguay, 2012, pp. 1-6, doi: 10.1109/TDC-LA.2012.6319109.es_ES
dc.identifier.isbn978-1-4673-2673-5
dc.identifier.urihttps://ieeexplore.ieee.org/document/6319109
dc.identifier.urihttp://hdl.handle.net/20.500.12272/10084
dc.language.isoenges_ES
dc.language.isoenges_ES
dc.publisherIEEE, Institute of Electrical and Electronics Engineerses_ES
dc.relation.projectidPID UTN ENUTNSF0004472es_ES
dc.rightsembargoedAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.rights.uriAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.use.es_ES
dc.sourceSixth IEEE/PES Transmission and Distribution: Latin America Conference and Exposition (T&D-LA), 1-6. (2012)es_ES
dc.subjectHarmonic distortiones_ES
dc.subjectState estimationes_ES
dc.subjectPower distributiones_ES
dc.subjectPower system harmonicses_ES
dc.titleErroneous data detection in the harmonic state estimation of a radial distribution system with distributed generationes_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
dc.type.versionpublisherVersiones_ES

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Carátula - Erroneous data detection in the harmonic state estimation of a radial distribution system with distributed generation.pdf
Size:
129.24 KB
Format:
Adobe Portable Document Format
Description:
Artículo principal y único

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: